MIL-DTL-5015 (solder) · MS3106A straight plug · Shell 12S · Arrangement 12S-3 · 2 x #16 socket · Class A
MIL-DTL-5015 / MS5015 (solder)
MS3106A straight plug
A - general duty, solid shell, solder contacts
12S
12S-3
2
#16
Socket (female)
Solder
13 A per contact
16 - 20 AWG
Threaded, single keyway
Aluminium alloy
Olive drab cadmium (conductive) / other finishes on request
Silver (standard) / gold on request
-55°C to +125°C
Two-wire power runs, sensors, lighting and heating circuits
QPL
Arrangement 12S-3 is a two-contact size-16 layout — the minimum practical circuit count in a threaded 5015 shell. It exists because the specification requires a mechanically keyed, environmentally tolerant two-wire connection, which a smaller commercial connector could not guarantee at the same vibration and temperature rating. Because only one keyway is provided, a 12S-3 in the same panel as another 12S-3 would be interchangeable, so equipment using two such connectors relies on cable labelling or on choosing a different arrangement.
| Airoadcon | Equivalent source 1 | Equivalent source 2 | Equivalent source 3 |
|---|---|---|---|
| Airoadcon / AVIC | MS3106A12S-3S | ||
| Amphenol | 97-3106A-12S-3S | ||
| ITT Cannon | CA3106A12S-3S | ||
| Souriau | 8516A12S-3S |
Two-contact 5015 plugs are typically power-only links — a heater, a solenoid, a lamp, or a single sensor loop — and are commonly sold as cable assemblies rather than loose connectors. Airoadcon supplies them with matching MS3102A box-mount or MS3100E wall-mount receptacles so a complete mating pair can be ordered together.